IMPORTANT SAFETY INFORMATION
Installation must be carried out in accordance with these instructions, and must be
conducted by designated, qualied and competent personnel.
1. Warning!
This shower can deliver scalding temperatures if not operated, installed
or maintained in accordance with the instructions, warnings and cautions
contained in this guide and on or inside the appliance.
If you require a thermostatic shower Mira produce a range which also limit the
maximum temperature, for more information our contact details can be found
on the back cover of this guide.
1.1. Products manufactured by us are safe and risk-free, provided that they are
installed, used and maintained in good working order, in accordance with our
instructions and recommendations.
1.2. Isolate the electrical and water supplies before commencing installation. The
electricity must be turned off at the mains and the appropriate circuit fuse
removed, if applicable.
1.3. Mains connections are exposed when the cover is removed.
1.4. Refer to the wiring diagram before making any electrical connections (refer to
the wiring diagram at the back of this guide).
1.5. Make sure that any pipework that could become frozen is properly insulated.
1.6. Having completed the installation, make sure that the user is familiar with the
operation of the appliance.
1.7. Make sure that this guide is left with the user.
1.8. DO NOT commission this appliance if water leaks from the unit or the heater
tank pressure relief valve.
1.9. DO NOT t any form of outlet control (e.g. Trigger handset) as the outlet acts
as a vent for the tank body. Only Mira recommended outlet ttings should be
used.
1.10. Make sure all electrical connections are tight, to prevent overheating.
1.11. Warning! DO NOT operate this appliance if it is frozen. Allow the appliance to
thaw before using. The shower unit must not be tted where it may be exposed
to freezing conditions.
1.12. This product is not suitable for areas with high humidity (i.e steam rooms).
Please consult your installer.
1.13. THIS APPLIANCE MUST BE EARTHED. MAKE SURE SUPPLEMENTARY
BONDING COMPLIES WITH THE “REQUIREMENTS FOR ELECTRICAL
INSTALLATIONS”.
The installation must be in accordance with the current edition of ’The Plugs
and Sockets etc. (Safety) Regulations’ in force at the time of installation, this
Mira Play is intended to be permanently connected to the xed electrical wiring
of the mains system.